Wire Size for 2.9 Amps

Typical copper wire gauges for 2.9 amps across common run lengths on a 120V circuit, sized to keep voltage drop under 3% and respect the NEC 240.4(D) small-conductor rule. At 2.9A the load sits in residential-branch territory where aluminum is not a typical conductor, so the table lists copper only. Actual install sizing depends on conductor material, insulation/termination temperature rating, cable type, ambient and bundling derates, and local code.

2.9A Wire Gauge by Distance

DistanceCopper GaugeV-Drop (Cu)NEC Status
25 ft 14 AWG 0.4553V (0.3794%) check_circle OK
50 ft 14 AWG 0.9106V (0.7588%) check_circle OK
75 ft 14 AWG 1.37V (1.14%) check_circle OK
100 ft 14 AWG 1.82V (1.52%) check_circle OK
125 ft 14 AWG 2.28V (1.9%) check_circle OK
150 ft 14 AWG 2.73V (2.28%) check_circle OK
175 ft 14 AWG 3.19V (2.66%) check_circle OK
200 ft 12 AWG 2.3V (1.91%) check_circle OK
250 ft 12 AWG 2.87V (2.39%) check_circle OK
300 ft 12 AWG 3.45V (2.87%) check_circle OK
400 ft 10 AWG 2.88V (2.4%) check_circle OK
500 ft 10 AWG 3.6V (3%) check_circle OK

Copper gauges use the NEC 240.4(D) branch-circuit cap, not raw 75°C ampacity.