How Many Amps Is 240 kW at 208V?

At 208V, 240 kW pulls approximately 783.74 amps on AC three-phase (PF 0.85). This is the case typical for commercial HVAC, industrial motors, rooftop units, and three-phase panel loads. Always verify against the equipment nameplate for actual install sizing.

240 kW at 208V, AC three-phase (PF 0.85)
783.74 Amps
240 kilowatts at 208V on AC three-phase ≈ 783.74 amps
AC Single Phase (PF 0.85)1,357.48 A
DC (ideal baseline)1,153.86 A
783.74

Formulas

DC: kW to Amps

I(A) = 1000 × P(kW) ÷ V(V)

1000 × 240 ÷ 208 = 240,003 ÷ 208 = 1,153.86 A

AC Single Phase (PF = 0.85)

I(A) = 1000 × P(kW) ÷ (PF × V(V))

240,003 ÷ (0.85 × 208) = 240,003 ÷ 176.8 = 1,357.48 A

AC Three Phase (PF = 0.85)

I(A) = 1000 × P(kW) ÷ (√3 × PF × VL-L), where VL-L is the line-to-line voltage

240,003 ÷ (1.732 × 0.85 × 208) = 240,003 ÷ 306.22 = 783.74 A

Equipment & Circuit Sizing

Energy Cost

240 kW costs $40.80/hour at $0.17/kWh (rates last reviewed April 2026). See breakdown.

Power Factor Reference (AC three-phase)

How the line current for 240 kW at 208V changes with load power factor, on the same AC three-phase circuit basis the rest of the page uses. DC has no power factor; PF 1.0 represents resistive AC loads.

Load TypePF240 kW at 208V (AC three-phase)
Resistive (heaters, incandescent)1666.18 A
Fluorescent lamps0.95701.24 A
LED lighting0.9740.2 A
Synchronous motors0.9740.2 A
Typical mixed loads0.85783.74 A
Induction motors (full load)0.8832.73 A
Computers (without PFC)0.651,024.89 A
Induction motors (no load)0.351,903.38 A

AC Conversion Comparison

On DC, 240kW at 208V draws 1,153.86A. AC single-phase at PF 0.85 pulls 1,357.48A because reactive current is added on top of the real power. Three-phase at the same voltage needs only 783.74A per line since the same 240kW is shared across three conductors instead of one.

Circuit TypeFormulaResult
DC240,003 ÷ 2081,153.86 A
AC Single Phase (PF 0.85)240,003 ÷ (0.85 × 208)1,357.48 A
AC Three Phase (PF 0.85)240,003 ÷ (1.732 × 0.85 × 208)783.74 A

Other kW Values at 208V

kWAC 3-Phase per line, PF 0.85AC 1-Phase PF 0.85
15 kW48.98 A84.84 A
18 kW58.78 A101.81 A
20 kW65.31 A113.12 A
22 kW71.84 A124.43 A
25 kW81.64 A141.4 A
30 kW97.97 A169.68 A
35 kW114.29 A197.96 A
40 kW130.62 A226.24 A
50 kW163.28 A282.81 A
60 kW195.93 A339.37 A
75 kW244.92 A424.21 A
100 kW326.56 A565.61 A
125 kW408.19 A707.01 A
150 kW489.83 A848.42 A
200 kW653.11 A1,131.22 A

Same kW, Other Voltages

Each destination page leads with the interpretation most common for that voltage, so the amps shown below use the same basis as the page you'd land on: single-phase for residential voltages, three-phase for commercial/industrial panel voltages, DC for low-voltage.

Frequently Asked Questions

240 kW at 208V draws about 783.74 amps on an AC three-phase circuit at PF 0.85. Alternate cases at the same voltage: 1,153.86A on DC, 1,357.48A on AC single-phase.
Three-phase at 208V draws 783.74A per line versus 1,357.48A single-phase. Less current per conductor means smaller wire and lower I²R losses.
DC: Amps = (kW × 1000) ÷ Volts. AC single-phase: Amps = (kW × 1000) ÷ (Volts × PF). AC three-phase: Amps = (kW × 1000) ÷ (VoltsL-L × √3 × PF).
240 kW costs $40.80 per hour at $0.17/kWh (US residential average, last reviewed April 2026). At 8 hours/day that is $9,792.12 per month.
240 kW equals 240,003 watts. Multiply kilowatts by 1000.
This calculator provides estimates for reference purposes only. Always consult a licensed electrician and verify compliance with the National Electrical Code (NEC) and local electrical codes before performing any electrical work.